Thanh khử tĩnh điện phòng nổ KASUGA PAS-701S/CSR

    Model: PAS-701S, CSR, SD-4, CSR-150P, CSR-2000P, CSR-2050P, CSR-2600P
    Hãng sản xuất: KASUGA DENKI,
    Tình trạng: Còn hàng
    Bảo hành: 12 tháng
    Giá:Liên Hệ
    • Thanh khữ tĩnh điện
    • Thanh khử ion tĩnh điện
    • Bộ khử tĩnh điện
    • Thanh khử ion tĩnh điện KASUGA DENKI
    • Thanh khu tinh dien KASUGA DENKI
    • Hệ thống khử tĩnh điện KASUGA DENKI
    • Thanh thổi ion khử tĩnh điện KASUGA DENKI

    Features

    • AC-type units that eliminate static by generating ions
    • The units apply the corona discharge method, which enables them to eliminate static without contacting the charged object.
    • The static eliminating electrode features a completely new structure that uses a ceramic dielectric element for capacitive coupling.
    • The static eliminating electrode uses chemical-resistant materials (such as toluene).
    • The high-voltage power supply device comes with a built-in protective circuit that shuts down the device and signals an alarm with a lamp and buzzer when it detects abnormal discharge of the static eliminating electrode or the high-voltage line, or abnormality of output voltage.
    • One high-voltage power supply device permits use of up to four static-eliminating electrodes and four branch connectors. The maximum length of the high-voltage cable is 31 meters including the electrode lead cable.

    Model

    PAS-701S, CSR, SD-4, CSR-150P, CSR-2000P, CSR-2050P, CSR-2600P

    Specifications

    High-voltage power supply device

    Model PAS-701S
    Rated output voltage AC7kV (at rated load)
    Load capacity Maximum: Three CSR-2600P electrodes and high-voltage cable that is 31-m long
    Minimum: One CSR-150P electrode and high-voltage cable that is 6.5-m long
    Output short-circuit current 5.2mA
    Protective circuit A built-in alarm circuit that detects abnormal discharge and output voltage fluctuation
    Input power AC100V (tap changer for switching to 110V, 200V or 220V)
    Frequency 60 Hz (switched to 50 Hz internally)
    Power consumption Approx. 50VA
    Operating environment Temperature: 0°C-40°C, Humidity: 35%-75% RH (no condensation)
    Insulation type E
    Installation location To be installed in a non-hazardous location

    Static-eliminating electrode

    Model CSR
    Ion generation method AC corona discharge
    Applied voltage AC7kV
    Electrode length 150 mm-2,600 mm (CSR-150P to CSR-2600P)
    Variable in steps of 50 mm within the above range.
    Effective static elimination current 0.4 μA/cm or above
    (at an installation distance of 20 mm and a charge potential of -5 kV)
    Installation distance 20 – 100mm
    (The distance must be within the above range and determined by measuring the potential after static elimination.)
    Operating environment Temperature: 0°C-40°C, Humidity: 35%-75% RH (no condensation)
    Installation site To be installed in a hazardous location

    Branch connector

    Model SD-4
    Type For two-way, three-way or four-way connection
    Connection method Metal connector
    Applied voltage AC7kV
    Operating environment Temperature: 0°C-40°C, Humidity: 35%-75% RH (no condensation)
    Installation site To be installed in a hazardous location