Thanh khử tĩnh điện phòng nổ KASUGA PAS-701S/CSR

Model: PAS-701S, CSR, SD-4, CSR-150P, CSR-2000P, CSR-2050P, CSR-2600P
Hãng sản xuất: KASUGA DENKI,
Tình trạng: Còn hàng
Bảo hành: 12 tháng
Giá:Liên Hệ
  • Thanh khữ tĩnh điện
  • Thanh khử ion tĩnh điện
  • Bộ khử tĩnh điện
  • Thanh khử ion tĩnh điện KASUGA DENKI
  • Thanh khu tinh dien KASUGA DENKI
  • Hệ thống khử tĩnh điện KASUGA DENKI
  • Thanh thổi ion khử tĩnh điện KASUGA DENKI

Features

  • AC-type units that eliminate static by generating ions
  • The units apply the corona discharge method, which enables them to eliminate static without contacting the charged object.
  • The static eliminating electrode features a completely new structure that uses a ceramic dielectric element for capacitive coupling.
  • The static eliminating electrode uses chemical-resistant materials (such as toluene).
  • The high-voltage power supply device comes with a built-in protective circuit that shuts down the device and signals an alarm with a lamp and buzzer when it detects abnormal discharge of the static eliminating electrode or the high-voltage line, or abnormality of output voltage.
  • One high-voltage power supply device permits use of up to four static-eliminating electrodes and four branch connectors. The maximum length of the high-voltage cable is 31 meters including the electrode lead cable.

Model

PAS-701S, CSR, SD-4, CSR-150P, CSR-2000P, CSR-2050P, CSR-2600P

Specifications

High-voltage power supply device

Model PAS-701S
Rated output voltage AC7kV (at rated load)
Load capacity Maximum: Three CSR-2600P electrodes and high-voltage cable that is 31-m long
Minimum: One CSR-150P electrode and high-voltage cable that is 6.5-m long
Output short-circuit current 5.2mA
Protective circuit A built-in alarm circuit that detects abnormal discharge and output voltage fluctuation
Input power AC100V (tap changer for switching to 110V, 200V or 220V)
Frequency 60 Hz (switched to 50 Hz internally)
Power consumption Approx. 50VA
Operating environment Temperature: 0°C-40°C, Humidity: 35%-75% RH (no condensation)
Insulation type E
Installation location To be installed in a non-hazardous location

Static-eliminating electrode

Model CSR
Ion generation method AC corona discharge
Applied voltage AC7kV
Electrode length 150 mm-2,600 mm (CSR-150P to CSR-2600P)
Variable in steps of 50 mm within the above range.
Effective static elimination current 0.4 μA/cm or above
(at an installation distance of 20 mm and a charge potential of -5 kV)
Installation distance 20 – 100mm
(The distance must be within the above range and determined by measuring the potential after static elimination.)
Operating environment Temperature: 0°C-40°C, Humidity: 35%-75% RH (no condensation)
Installation site To be installed in a hazardous location

Branch connector

Model SD-4
Type For two-way, three-way or four-way connection
Connection method Metal connector
Applied voltage AC7kV
Operating environment Temperature: 0°C-40°C, Humidity: 35%-75% RH (no condensation)
Installation site To be installed in a hazardous location