Thiết bị hiệu chuẩn nhiệt độ Druck Liquid TC 255

Model: Liquid TC 255
Hãng sản xuất: DRUCK,
Tình trạng: Còn hàng
Bảo hành: 12 tháng
Giá:Liên Hệ
  • Máy hiệu chuẩn nhiệt độ
  • Thiết bị hiệu chuẩn nhiệt độ DRUCK
  • Bộ hiệu chuẩn nhiệt độ DRUCK
  • Thiết bị hiệu chuẩn can nhiệt
  • Thiết bị hiệu chuẩn cặp nhiệt điện
  • Thiết bị hiệu chuẩn cảm biến nhiệt độ

Overview

Features

  • Dry block or liquid bath configurations
  • Temperature range from -35°C to 650°C
  • Accuracy from 0.2°C
  • Stability 0.05°C
  • Rapid heating and cooling
  • Light weight and robust for field use
  • Choice of interchangeable well inserts
  • Easy to set-up and use

Description

The Druck TC Series Dry Block / Liquid Bath Temperature Calibrators provide solutions for testing temperature devices over a range of temperatures from -30°F to 1200°F (-35 to 650°C) with a choice of dry block and liquid bath configurations to accommodate virtually any type, shape and size of sensor.

These dry block calibrators incorporate the latest metal block and electronic control technology and offer a choice of precision bored well inserts to accommodate a wide range of test devices. The two models available are the DryTC 165 that generates temperatures from -35°C to 165°C and the DryTC 650 that generates temperatures from ambient to 650°C. Both models provide high accuracy, excellent sent point stability and rapid heating and cooling times

Dry block calibrators greatly simplify the test and calibration of process sensor heads, probes, switches and thermometers, but optimum performance relies on a good fit of the device in the well insert. To facilitate this, a range of insertion sleeves are available with hole diameters to suit the most common probes and devices.

These multi-purpose calibrators combine the portability of dry block calibrators with the flexibility of liquid immersion baths to enable the testing and calibration of virtually any shape and size of devices. The calibrators can be re-configured by the user to function as a liquid bath, as an infra-red black body source and as a dry block calibrator with interchangeable inserts. The latest heating and electronic control technology, combined with continuous liquid agitation of the fluid bath, provide high accuracy and stability throughout the large homogeneous measuring zone. The calibrators are factory configured as liquid baths and are provided with a bath cover to hold up to 5 devices while reducing heat loss from the surface of the liquid medium. For transportation a leak-proof sealing cover is also provided as standard. Optionally the temperature calibrators can be configured with additional capabilities including interchangeable liquid baths, a black body source and dry block interchangeable inserts. Two models are available.

THÔNG SỐ KỸ THUẬT

Model LiquidTC 165 LiquidTC 255
Temperature Range Room Temperature (RT) to 155°C (-30° to 310°F option) with TCL 10 oil supplied
25° to 165°C (-77° to 330 °F option) with optional TCL 50 oil
Ambient to 255°C
(Ambient to 490 °F option)
Heat Well Dia 60 mm/depth 170 mm (150 mm working depth)
Measuring Zone 0 to 40mm from the bottom of the insert
Stability 0.05°C
Accuracy
Standard Liquid Bath – LI 0.2°C 0.2°C
Dry Block Option – DB 0.3°C 0.4°C
Infrared Black Body Option – IR 0.5°C 0.5°C
Black Body Emissivity 0.9994
Display
Display Range -50 to 165°C 0 to 255°C
Measurement Resolution 0.01° from -9.99 to 99.99 otherwise 0.1°C
Setting Resolution 0.1°C
Standard Features
Functions Controller off, manual control, operating service hours, set-point memory, rate control °C/min, test profile
Power Requirements
Supply Voltage 100 to 240V AC 50/60Hz
Power Consumption 400VA nominal 1000VA nominal
Dimensions/Weight
Width 210mm 150mm
Height 380 + 50mm 330+68mm
Depth 300mm 270mm
Weight 12.5kg 7.5kg
Environmental
Ambient Temperature 10°C to 50°C (50°F to 122°F)
Specifications valid at 18 °C to 28 °C (65 °F to 82 °F) ambient temperature. Minimum and maximum temperatures may not be achieved over the full ambient temperature range.
Ambient Humidity To 80% RH (non-condensing)
Storage Temperature From -10 to 60°C (14 to 140°F)
Recommended Operating Environment Indoor use. Not for use in potentially explosive atmospheres
Compliance EN6326 (EMC), EN61010 Oelectrical safety), EU directive (RoHS, REACH, WEEE)